75653200001
Laboratory fume hood, 1200x2730x970mm, 6 sockets 230V, 1 base cabinet B-1100mm 2 hinged doors
Listprice: 6.036,00 € valid until 2024-12-31
This item automatically includes delivery and installation by the manufacturer. Delivery times to be arranged individually Construction Installation cell made of metal profiles Surface powder-coated Back wall Exhaust back wall with a pre-mounted, reversible air deflection wall made of HPL Double-row stand rod holder Ceiling Ceiling with glass cutout for lighting and explosion vent LED work area lighting (4000 K, 1700 lm) Exhaust spigot DN 250 mm Table frame Supporting construction made of rectangular profiles Height adjustable from 0-30 mm Surface powder-coated Valve panel for media control elements Side wall Side walls melamine resin-coated Vertical energy posts with internal sockets External individual switch for sockets Holder for the control display of the control unit Residual current circuit breaker and automatic fuse Front slider made of special aluminum profiles as a vertically easy-running sliding frame Counterbalanced with counterweights and integrated fall protection Two horizontal sliders with recessed handles Fixed glass transom Glazing: laminated safety glass Large-format stoneware slab (EN 14879-6) All-around raised edge (flow-optimized) Width 1100mm 2 hinged doors with external pivot axis for opening up to 270° Internally height-adjustable shelf on steel shelf supports in perforated row for setting the desired individual height Shelf coated with protective edge all around and secured against pulling out Brushed stainless steel handles Monitoring unit to control operating status Visual and acoustic warning when the required exhaust air volume flow is undershot Control of the lighting Status display for the position of the front slider Battery backup in case of power failure 1 junction box for connecting the on-site supply line 5×6 mm² 35A 1 small distributor in exhaust post 1 residual current circuit breaker type A 2 circuit breakers B16A 1-pole 1 circuit breaker B10A 1-pole 6 sockets 230V inside, switchable outside Compressed air loss 23 Pa Exhaust air volume flow 520 m³/h Exhaust spigot diameter 250 mm For connection to existing exhaust system Table exhaust according to DIN EN 14175 Height 2730 mm Width 1200 mm Depth 970 mm Table height 900 mm Clear working height 1500 mm Opening height of front slider 1800 mm Sliding window (vertical, easy-running) Work surface made of laboratory ceramic for maximum stress Flow-optimized raised edge Highly efficient exhaust system Ergonomically optimized control elements Flow baffles (removable for easy cleaning) Maintenance-friendly positioned revision panel Ergonomically arranged sockets in side posts Volume flow monitoring (differential pressure measurement) Control element for exhaust control